HVAC, Boilers & Heating

Boiler, heat pump, and furnace error codes for Vaillant, Viessmann, Buderus, Worcester Bosch, and Carrier systems.

15 codes indexed
F.28Vaillant

Vaillant Boiler Fault Code F.28: Ignition Failure Lockout

Vaillant ecoTEC / atmoTEC failed to detect an ionization flame signal after 3 consecutive ignition attempts—caused by interrupted gas supply, empty prepayment credit, frozen condensate pipes, fouled/worn electrodes, air/flue blockage, or gas valve/PCB faults.

F.22Vaillant

Vaillant Boiler Fault Code F.22: Low System Water Pressure / Dry Fire

Central heating water pressure dropped below Vaillant's safe minimum (~< 1.0 bar cold, locking out around 0.3–0.5 bar)—fixed cleanly by repressurising via the filling loop to 1.0–1.5 bar cold unless leaks or expansion vessel wear cause recurring drops.

EAWorcester Bosch

Worcester Bosch Greenstar EA Fault Code (Flame Detection / Ignition Lockout)

Flame was not detected or failed to stabilize during Worcester Bosch Greenstar ignition—fixed safely via checking household gas supply, thawing frozen exterior plastic condensate pipes, and holding the blue Reset button ~3 seconds (once or twice max).

F4Viessmann

Viessmann Vitodens Fault Code F4: Burner Ignition / Flame Signal Error

Viessmann Vitodens gas boiler failed to establish or sustain a flame signal during ignition—officially attributed to dirty/worn ionization & ignition electrodes, gas supply interruption, frozen exterior condensate drains, flue blockages, or gas valve/PCB failure.

F.29Vaillant

Vaillant Boiler Fault Code F.29: Flame Extinguished During Running

Burner ignited initially yet lost its flame signal mid-operation—most commonly triggered by a frozen or algae-blocked exterior condensate drain backing wastewater up into the trap/sump, flue gas recirculation, gas pressure dips, or worn ionization probes.

U4Daikin

Daikin AC & Heat Pump Error Code U4: Indoor-Outdoor Communication Failure

Data transmission dropped between indoor air handler(s) and outdoor condenser—officially diagnosed via 5-minute full breaker reset, shielded twisted-pair F1/F2 wiring checks (infinite resistance unhooked, 14–18 V DC pulsing nominal), single-end shield grounding, and PCB isolation.

E9Worcester Bosch

Worcester Bosch E9 Fault Code: Central Heating Overheat Safety Limiter (105 °C)

High-limit lockout triggered when the central heating flow Safety Temperature Limiter exceeds `105 °C` (often logged with sub-codes `219`, `220`, `221`, or `224`)—check cold pressure (`1.0–1.5 bar`) and open valves, then book a Gas Safe engineer.

F.75Vaillant

Vaillant Boiler Fault F.75: No Pressure Jump Detected on Pump Start

Vaillant's PCB demands a dynamic `≥ 0.05 bar` (`50 mbar`) pressure pulse when starting the circulation pump—if static pressure sits below `1.0 bar` or the water pressure sensor/pump fails, burner ignition locks out on `F.75`.

F2Viessmann

Viessmann Boiler Fault F2: Overheat Safety Temperature Limiter (STB) Tripped

Burner safety lockout triggered when primary heat-exchanger flow hits `~90–100 °C` and trips the hardwired **Safety Temperature Limiter (STB)**—check `1.0–1.5 bar` pressure, radiator flow, or frozen condensate drain; do NOT force repeated resets.

F.20Vaillant

Vaillant Boiler Fault F.20: Safety Switch-Off via Temperature Limiter (STB)

Hardwired Safety Temperature Limiter (**STB**) tripped independently near `~97 °C` to stop burner overheat—check cold pressure (`1.0–1.5 bar`) and open valves, perform one cool reset, and call a certified engineer if `F.20` repeats.

3YBuderus

Buderus Boiler Fault 3Y (215): Air Pressure Switch & Flue Draft Failure

Burner lockout paired with service code `215` when the differential air pressure switch fails to switch upon fan start—check exterior flue outlet safely, perform one reset, then call a certified SHK/Gas Safe engineer.

6ABuderus

Buderus Boiler Fault 6A (227): No Flame Detected / Ionization Failure

Burner lockout paired with service code `227` after ignition attempts fail to establish stable micro-ampere (`µA`) ionization current—confirm external gas valves are open, press Reset once, and book a certified heating engineer.

A5Daikin

Daikin AC / Heat Pump A5: Freeze-Up Protection or High-Pressure Coil Limit

Daikin stops the compressor on `A5` when indoor heat-exchanger coil drops `< 0 °C` in Cooling (freeze protection) or rises `> 61 °C` in Heating (high pressure)—clean dirty air filters first, check fan airflow, and verify coil thermistor / multi-split wiring.

F5Viessmann

Viessmann Boiler Fault F5 (F05): Air Pressure Switch / Flue Draft Error

Combustion safety lockout when the differential air pressure switch fails to open before blower start or close under differential pressure (`Pa`)—check outside flue outlet safely, try one reset, then call a certified heating engineer.

H07Buderus

Buderus Boiler Fault H07 (1017): Heating System Water Pressure Too Low

Blocking/status code `H07` (`1017`) halts firing when cold system water pressure drops under minimum threshold (`< 0.8 bar` / critical `< 0.2 bar`)—safely refill via external loop to `1.0–1.5 bar`, bleed radiators, or service leaking expansion vessels.