Worcester Bosch Greenstar EA Fault Code (Flame Detection / Ignition Lockout)
Flame was not detected or failed to stabilize during Worcester Bosch Greenstar ignition—fixed safely via checking household gas supply, thawing frozen exterior plastic condensate pipes, and holding the blue Reset button ~3 seconds (once or twice max).
Worcester Bosch fault code EA means flame not detected: the Greenstar boiler attempts spark ignition yet fails to register an ionization flame signal and locks out safely. Start with safe homeowner checks: verify other gas appliances (cooker/hob) work, check external white/grey plastic condensate discharge pipes in freezing weather (thaw slowly with warm, never boiling water), and hold the blue Reset button for ~3 seconds (at most 1–2 times). If EA immediately returns—or if you smell gas—stop resetting and never tamper with the gas valve or open the boiler casing; book a Gas Safe / certified heating engineer (€0 DIY checks; £95–£410 / €125–€460 service).
- Safe to Operate?
- No — Risk of Damage
- DIY Difficulty
- Professional Recommended
- System
- Gas Ignition & Flame Sensing
- Professional Repair
- $145 – $540
What This Fault Code Means
On Worcester Bosch Greenstar models (identical to Bosch/Junkers EA), the burner board commands the gas valve open, triggers the ignition electrodes, and monitors micro-current across the flame ionization probe. If gas stops flowing, condensate backs up from a frozen outdoor pipe, or corroded/carbon-coated electrodes or a sticking gas valve break ignition/flame sensing, EA locks the boiler off safely.
Common Symptoms
- Control panel flashes
EA(often accompanied by a blue warning light or spanner symbol) with zero heat/hot water - Audible sparking/clicking ignition attempts followed by safety lockout silence
- Commonly triggered during sub-zero cold snaps when external plastic condensate drains freeze solid
Most Likely Root Causes
- Frozen or blocked exterior white/grey plastic condensate discharge pipe backing wastewater into the sump
- Interrupted property gas supply, shutoff boiler gas cock, or empty prepayment gas meter credit
- Corroded, worn, or soot-coated ignition electrodes / ionization flame probe or frayed HT lead
- Blocked flue/air intake terminal, faulty gas valve assembly (sticking coil/wrong inlet pressure), or PCB control fault
Technical Thresholds & Specifications
| Parameter / Condition | Factory Spec / Threshold |
|---|---|
| Official Code Meaning Identical Bosch/Junkers EA flame-sensing safety code | Flame not detected / Ignition lockout |
| Reset Button Procedure Repeated resets without fixing cause risk unburnt gas buildup | Hold blue Reset button ~3 seconds (max 1–2×) |
| Cold-Weather Trigger Thaw externally ONLY using warm (never boiling) water | Frozen white/grey plastic condensate pipe |
| Gas Valve & Probe Rule Never open boiler casing or adjust gas valve settings yourself | Gas Safe / Certified Engineer Strictly Required |
Commonly Affected Models & Service Bulletins
- Worcester Bosch Greenstar i / Si / CDi / Ri Condensing Boilers
- Worcester Bosch Greenstar 2000 / 4000 / 8000 Life & Style Series
- Bosch / Junkers Cerapur & Condens Boilers (equivalent `EA` code)
Diagnostic Checks Before Replacing Parts
Verify the exact faulty component before ordering replacements.
- 1Safety Check: If you smell raw gas, do NOT press Reset or toggle switches—shut off the emergency gas valve, open windows, and call the national gas emergency helpline immediately.
- 2Test whether a gas stove/hob works cleanly (and check meter credit if applicable) plus inspect the outdoor white/grey plastic condensate pipe for ice buildup during freezing weather.
- 3Press and hold the blue Reset button (or touch reset symbol) for ~3 seconds once; never repeat resets over and over, and leave all internal gas-valve, electrode, and flue work to a Gas Safe engineer.
Interactive Symptom Triage
Answer 3 quick checks to narrow down the faulty component before spending money on parts.
Do your kitchen gas hob/other gas appliances fail to light as well?
Step-by-Step Troubleshooting & Fix
Tools & Parts Reference
- 1Verify household gas supply is uninterrupted and check any exposed external plastic condensate pipe for frost/ice.
- 2If frozen outside, pour warm (never boiling) water slowly along the plastic condensate pipe or hold a wrapped hot-water bottle against the frozen elbow until clear.
- 3Hold the Worcester Bosch blue Reset button for ~3 seconds once (up to 1–2 checks maximum).
- 4If
EAreturns: stop resetting and hire a Gas Safe / certified heating engineer to inspect gas valve inlet/burner pressure, clean or replace corroded ignition electrodes & ionization probe, check condensate siphon cleanliness, and verify safe combustion.
Estimated Repair Cost Benchmark
Typical DIY parts and certified technician labor ranges. Select a currency below.
| Repair Path | USD |
|---|---|
| DIY Parts Only | $0 |
| Professional Repair (Parts + Labor) | $145 – $540 |
Certified Technician Service Checklist
This fault involves sealed safety, gas, or high-voltage systems. Share these details when requesting a repair quote.
- Share exact brand & fault code: Worcester Bosch EA (Gas Ignition & Flame Sensing)
- Record appliance/boiler serial, model plate, or pressure reading before calling
- Typical certified technician range: $145 – $540
Frequently Asked Questions
How do I reset a Worcester Bosch boiler showing EA?
Press and hold the blue Reset button (or touch Reset icon on newer Greenstar panels) for roughly 3 seconds once after checking gas supply and exterior condensate pipes. Never press Reset repeatedly if EA returns right away—unburnt gas or valve faults require an engineer.
Can I fix or adjust the gas valve myself for an EA fault?
Never. Gas valves regulate flammable gas supply and require calibrated combustion analyzers plus legal Gas Safe / HVAC certification to test, adjust, or replace.
Related Searches & Questions
Verified Official & Engineering References
Related Fault Codes
HVAC & Boilers →Vaillant Boiler Fault Code F.28: Ignition Failure Lockout
Vaillant ecoTEC / atmoTEC failed to detect an ionization flame signal after 3 consecutive ignition attempts—caused by interrupted gas supply, empty prepayment credit, frozen condensate pipes, fouled/worn electrodes, air/flue blockage, or gas valve/PCB faults.
Vaillant Boiler Fault Code F.29: Flame Extinguished During Running
Worcester Bosch E9 Fault Code: Central Heating Overheat Safety Limiter (105 °C)
Vaillant Boiler Fault Code F.22: Low System Water Pressure / Dry Fire
Viessmann Vitodens Fault Code F4: Burner Ignition / Flame Signal Error