# Worcester Bosch EA: Worcester Bosch Greenstar EA Fault Code (Flame Detection / Ignition Lockout)

> **Quick Answer:** Worcester Bosch fault code `EA` means **flame not detected**: the Greenstar boiler attempts spark ignition yet fails to register an ionization flame signal and locks out safely. Start with safe homeowner checks: verify other gas appliances (cooker/hob) work, check external white/grey plastic **condensate discharge pipes** in freezing weather (thaw slowly with **warm, never boiling water**), and hold the **blue Reset button for ~3 seconds** (at most **1–2 times**). If `EA` immediately returns—or if you smell gas—**stop resetting and never tamper with the gas valve or open the boiler casing**; book a Gas Safe / certified heating engineer (€0 DIY checks; £95–£410 / €125–€460 service).

- **URL:** https://faultcodes.org/hvac/worcester-bosch-ea
- **Category:** HVAC, Boilers & Heating
- **Brand / Standard:** Worcester Bosch
- **System Area:** Gas Ignition & Flame Sensing
- **Severity:** Critical — Stop Immediately
- **Safe to Operate?:** No — Risk of Damage
- **DIY Difficulty:** Professional Recommended
- **Updated:** 2026-11-22T00:00:00Z

## What This Fault Code Means
On Worcester Bosch Greenstar models (identical to Bosch/Junkers `EA`), the burner board commands the gas valve open, triggers the ignition electrodes, and monitors micro-current across the flame ionization probe. If gas stops flowing, condensate backs up from a frozen outdoor pipe, or corroded/carbon-coated electrodes or a sticking gas valve break ignition/flame sensing, `EA` locks the boiler off safely.

## Technical Thresholds & Specifications
| Parameter / Condition | Factory Spec / Threshold | Note |
| --- | --- | --- |
| Official Code Meaning | Flame not detected / Ignition lockout | Identical Bosch/Junkers EA flame-sensing safety code |
| Reset Button Procedure | Hold blue Reset button ~3 seconds (max 1–2×) | Repeated resets without fixing cause risk unburnt gas buildup |
| Cold-Weather Trigger | Frozen white/grey plastic condensate pipe | Thaw externally ONLY using warm (never boiling) water |
| Gas Valve & Probe Rule | Gas Safe / Certified Engineer Strictly Required | Never open boiler casing or adjust gas valve settings yourself |

## Commonly Affected Models & Service Bulletins
- Worcester Bosch Greenstar i / Si / CDi / Ri Condensing Boilers
- Worcester Bosch Greenstar 2000 / 4000 / 8000 Life & Style Series
- Bosch / Junkers Cerapur & Condens Boilers (equivalent `EA` code)

## Common Symptoms
- Control panel flashes `EA` (often accompanied by a blue warning light or spanner symbol) with zero heat/hot water
- Audible sparking/clicking ignition attempts followed by safety lockout silence
- Commonly triggered during sub-zero cold snaps when external plastic condensate drains freeze solid

## Most Likely Root Causes
- Frozen or blocked exterior white/grey plastic **condensate discharge pipe** backing wastewater into the sump
- Interrupted property gas supply, shutoff boiler gas cock, or empty prepayment gas meter credit
- Corroded, worn, or soot-coated **ignition electrodes / ionization flame probe** or frayed HT lead
- Blocked flue/air intake terminal, faulty **gas valve** assembly (sticking coil/wrong inlet pressure), or PCB control fault

## Tools & Parts Reference
- Warm (non-boiling) water / hot-water bottle (for frozen exterior condensate pipe only)
- Certified engineer calibrated gas pressure manometer & flue analyzer
- OEM Worcester Bosch ignition electrode & ionization probe kit (pro install)

## Step-by-Step Troubleshooting & Fix
1. Verify household gas supply is uninterrupted and check any exposed external plastic condensate pipe for frost/ice.
2. If frozen outside, pour **warm (never boiling)** water slowly along the plastic condensate pipe or hold a wrapped hot-water bottle against the frozen elbow until clear.
3. Hold the Worcester Bosch **blue Reset button for ~3 seconds** once (up to 1–2 checks maximum).
4. If `EA` returns: **stop resetting** and hire a **Gas Safe / certified heating engineer** to inspect gas valve inlet/burner pressure, clean or replace corroded ignition electrodes & ionization probe, check condensate siphon cleanliness, and verify safe combustion.

## Estimated Repair Cost Benchmark
| Currency | DIY Parts Only | Professional Repair (Parts + Labor) |
| --- | --- | --- |
| USD | $0–$0 | $145–$540 |
| GBP | £0–£0 | £95–£410 |
| CAD | CA$0–CA$0 | CA$190–CA$660 |
| EUR | €0–€0 | €125–€460 |
| CHF | CHF 0–CHF 0 | CHF 195–CHF 670 |

## Frequently Asked Questions
### How do I reset a Worcester Bosch boiler showing EA?
Press and hold the **blue Reset button** (or touch Reset icon on newer Greenstar panels) for roughly **3 seconds** once after checking gas supply and exterior condensate pipes. Never press Reset repeatedly if `EA` returns right away—unburnt gas or valve faults require an engineer.

### Can I fix or adjust the gas valve myself for an EA fault?
**Never.** Gas valves regulate flammable gas supply and require calibrated combustion analyzers plus legal Gas Safe / HVAC certification to test, adjust, or replace.