P0142 Fault Code: O2 Sensor Circuit Bank 1 Sensor 3
OBD-II P0142 (Fuel Trim & Air/O2 Metering): O2 Sensor Circuit Bank 1 Sensor 3.
OBD-II fault code P0142 indicates O2 Sensor Circuit Bank 1 Sensor 3. Usually safe for short trips if no severe drivability or safety warnings are active. Typical professional repair costs $65–$270.
- Safe to Operate?
- Yes (Short Term)
- DIY Difficulty
- Easy (Basic Tools)
- System
- Fuel Trim & Air/O2 Metering
- Professional Repair
- $65 – $270
What This Fault Code Means
Sensor 3 is a third oxygen sensor on bank 1, behind a second converter or converter brick. It only exists on some vehicles – documented for Jaguar Land Rover's 3.0 V6 supercharged (2013–2016, where sensor 2 is 'mid-cat' and sensor 3 'post-cat') and Ford systems that monitor part of the converter volume. P0142 is the general circuit code of this sensor. Jaguar Land Rover lists it with P0143, P0144 and P0147 for the post-cat sensor and names software (fixed by reconfiguring the engine module) and water-induced thermal shock as causes. No published thresholds exist for sensor 3; the logic follows the sensor 2 checks (P0136). When it fails, the control module stops the downstream trim and cannot evaluate the converter; there is no limp mode.
Common Symptoms
- Check engine light on (usually after two drive cycles)
- Catalyst monitor readiness not set
- Usually no noticeable change in driving
Most Likely Root Causes
- Sensor 3 faulty (thermal shock, ageing)
- Wiring or connector under the car damaged or corroded
- Engine module software (Jaguar Land Rover)
- Exhaust leak ahead of sensor 3
Diagnostic Checks Before Replacing Parts
Verify the exact faulty component before ordering replacements.
- 1Read stored freeze-frame data and companion codes alongside P0142.
- 2Inspect electrical connectors, fuses, and harnesses connected to Oxygen Sensor Bank1 Sensor3.
- 3Verify live sensor telemetry before ordering replacement components.
Interactive Symptom Triage
Answer 3 quick checks to narrow down the faulty component before spending money on parts.
Are any companion fault codes stored alongside P0142?
Step-by-Step Troubleshooting & Fix
- 1Scan for companion fault codes and address upstream circuit issues first.
- 2Visually inspect wiring harnesses, plugs, and hoses around Oxygen Sensor Bank1 Sensor3.
- 3Test component voltage, resistance, or mechanical actuation with diagnostic tools.
- 4Repair damaged wiring or install an OEM-grade replacement Oxygen Sensor Bank1 Sensor3.
- 5Clear fault memory and run a verification cycle to confirm P0142 does not return.
Estimated Repair Cost Benchmark
Typical DIY parts and certified technician labor ranges. Select a currency below.
| Repair Path | USD |
|---|---|
| DIY Parts Only | $23 – $113 |
| Professional Repair (Parts + Labor) | $65 – $270 |
Frequently Asked Questions
Is it safe to keep operating with fault code P0142?
Usually safe for short trips if no severe drivability or safety warnings are active.
How much does it cost to repair P0142?
DIY replacement parts average $23–$113, while professional service averages $65–$270.
Will resetting P0142 fix the problem permanently?
No. Clearing the fault code only removes the stored alert temporarily; the code returns if the underlying fault persists.
Related Searches & Questions
Manufacturer & Technical Reference
OBD-II Technical Reference (Fuel Trim & Air/O2 Metering)