Junkers / Bosch Boiler Fault EA: No Ionization Flame Detected After Ignition

Most common Junkers Cerapur / Bosch Condens lockout: no stable ionization current (< 1.5–2 µA) is detected after the ignition attempt—check for gas smell, confirm the gas supply and defrost any frozen exterior condensate pipe with warm water, hold Reset for ~3 seconds once or twice, then call a certified engineer.

Quick AnswerCritical — Stop Immediately

Fault code EA on Junkers (Cerapur, Cerastar, Cerasmart) and Bosch Condens boilers means no ionization flame was detected after the ignition sequence: the boiler clicks and tries to ignite, yet fails to establish a stable flame signal (> ~1.5–2 µA DC). Safely verify whether there is any gas odor (if so, close the main gas valve, open windows, avoid electrical switches, and evacuate), confirm the appliance gas valve is open and another gas appliance works, thaw any frozen external plastic condensate pipe with warm—never boiling—water, and hold the Reset / chimney-sweep reset button for ~3 seconds (maximum 1–2 attempts). Never open the sealed combustion cover or adjust the gas valve—a Gas Safe / certified DVGW heating engineer must measure dynamic gas flow pressure (~20 mbar), clean/replace ignition and ionization electrodes, verify CO₂ combustion ratio, and clear internal condensate traps ($145–$540 / €125–€460).

Safe to Operate?
No — Risk of Damage
DIY Difficulty
Professional Recommended
System
Flame Detection / Ignition
Professional Repair
$145 – $540

What This Fault Code Means

During every startup on Heatronic III / IV or Bosch BC20/UI300 controls, the fan pre-purges, the ignition transformer arcs across the spark electrode, and the gas combination valve opens for a short safety window (~3–5 s). Combustion plasma must immediately rectify AC probe voltage into a continuous DC microampere signal (≥ 2 µA, typically 4–10 µA) on the ionization electrode. Lack of gas, backed-up condensate drowning the burner, fouled ceramic probes, reversed electrical polarity (L/N), or a faulty gas valve causes EA lockout.

Common Symptoms

  • Display flashes EA (often with red warning LED) and neither heating nor domestic hot water runs
  • Rapid spark clicking heard inside the boiler for 3–5 seconds followed by quiet shutdown
  • Commonly appears during sub-zero winter nights (frozen external condensate drain) or after gas meter/pipe maintenance

Most Likely Root Causes

  • Interrupted gas supply, closed appliance/meter gas valve, air pocket in newly serviced gas pipe, or failed gas pressure regulator
  • Frozen external condensate discharge pipe or choked internal condensate trap backing water into the combustion chamber
  • Worn, carbon-fouled, bent, or cracked ignition / ionization electrode assembly or damaged HT spark lead
  • Sticking gas combination valve, improper CO₂ air-gas ratio, blocked concentric flue exhaust recirculation, or faulty Heatronic ignition PCB

Technical Thresholds & Specifications

Parameter / ConditionFactory Spec / Threshold
Ionization Detection Minimum

Evaluated across ~3–5 s ignition safety time on Heatronic / Bosch controllers

≥ ~1.5–2.0 µA DC (Normal run ~4–10 µA)
Natural Gas Flow Pressure

Significant drop during burner start starves ignition and causes EA

20 mbar nominal (17–25 mbar E/LL; 50 mbar LPG)
Reset Procedure

Repeated resets without gas/condensate checks risk unburnt gas buildup

Hold Reset ~3 seconds (max 1–2 attempts)
Safety & Access Standard

Gas valve calibration and electrode replacement require flue gas analyzer

Gas Safe / Certified DVGW Engineer Only

Commonly Affected Models & Service Bulletins

  • Junkers Cerapur / CerapurComfort / CerapurSmart / CerapurAcu (ZSB, ZWB, ZWBR Series)
  • Junkers Cerastar / Ceraclass / Ceramini Gas Wall-Hung Boilers
  • Bosch Condens 2000W / 3000W / 5000W / 7000iW / 9000iW Series

Diagnostic Checks Before Replacing Parts

Verify the exact faulty component before ordering replacements.

  1. 1Immediate safety check: sniff for raw gas around the boiler and meter; if any gas smell exists, shut off the main gas valve, ventilate, do not flip electrical switches, and call gas emergency services.
  2. 2Confirm the boiler's external gas isolation cock is inline (open) and test whether a gas hob/stove burns steadily; during freezing weather, inspect any external condensate pipe for ice blockages (thaw safely from outside only using warm water).
  3. 3Hold the Reset button for ~3 seconds (1–2 attempts max). Certified engineer steps: measure static (~20–25 mbar) and dynamic flowing gas pressure during ignition, inspect/clean condensate siphon, measure ionization µA DC, test spark gap/ignition transformer, check mains L/N/PE grounding, and calibrate flue CO₂ (~8.5–9.5% natural gas).

Interactive Symptom Triage

Answer 3 quick checks to narrow down the faulty component before spending money on parts.

Check 1 of 3

Are other gas appliances (such as a kitchen gas hob) also failing to burn, or is the external gas valve closed?

Step-by-Step Troubleshooting & Fix

Tools & Parts Reference

Warm (never boiling) water only for thawing exterior plastic condensate linesCertified engineer: Digital gas manometer (mbar), µA multimeter & flue gas analyzer (CO/CO₂)Certified engineer: OEM Junkers/Bosch ignition & ionization electrode kit + gaskets
  1. 1Verify gas supply availability (open gas valve, active gas meter credit/flow) and rule out any smell of gas.
  2. 2If sub-zero weather froze an outside plastic condensate pipe, slowly pour warm (never boiling) water over the exterior pipe elbow until the ice plug clears.
  3. 3Hold the Reset button for ~3 seconds (maximum 1–2 times); if EA returns, switch off the boiler electrical spur and do not force further resets.
  4. 4Call a Gas Safe / certified SHK heating engineer to flush the internal condensate trap, clean or replace ignition and ionization electrodes, verify dynamic gas flow pressure and gas combination valve modulation, and calibrate CO₂ combustion values.

Estimated Repair Cost Benchmark

Typical DIY parts and certified technician labor ranges. Select a currency below.

Currency:
Repair PathUSD
DIY Parts Only$0
Professional Repair (Parts + Labor)$145 – $540

Certified Technician Service Checklist

This fault involves sealed safety, gas, or high-voltage systems. Share these details when requesting a repair quote.

  • Share exact brand & fault code: Junkers / Bosch EA (Flame Detection / Ignition)
  • Record appliance/boiler serial, model plate, or pressure reading before calling
  • Typical certified technician range: $145 – $540

Frequently Asked Questions

How do you properly reset Junkers / Bosch fault EA?

First verify gas is available and external condensate lines aren't frozen, then press and hold the Reset button for about 3 seconds (1–2 tries maximum). Never bypass safeties or repeatedly hammer Reset if EA returns.

Why does Junkers EA happen suddenly during freezing winter weather?

Condensing boilers discharge acidic condensate water; if an exposed outdoor drain pipe freezes solid, condensate backs up inside the combustion chamber, drowning the burner and spark electrodes and causing immediate EA lockout.