# Viessmann F2: Viessmann Boiler Fault F2: Overheat Safety Temperature Limiter (STB) Tripped

> **Quick Answer:** Fault code **F2** on Viessmann Vitodens and Vitopend boilers means the **Safety Temperature Limiter (STB)** has tripped and locked out the burner because internal flow temperatures climbed into overheat territory (`~90–100 °C` depending on model limits). Safely check cold boiler gauge pressure (`1.0–1.5 bar`), confirm multiple radiator valves are open (not choked shut), check exterior plastic condensate lines in freezing weather, and try **one single reset** once cooled. Because repeated STB resets mask severe dry-firing hazards, if `F2` returns immediately you must leave the casing closed and call a Gas Safe / certified heating engineer to inspect the circulation pump, sludged plate heat exchanger, airlocks, and STB sensor ($140–$540 / £100–£390).

- **URL:** https://faultcodes.org/hvac/viessmann-f2
- **Category:** HVAC, Boilers & Heating
- **Brand / Standard:** Viessmann
- **System Area:** Overheat Protection & Circulation
- **Severity:** Critical — Stop Immediately
- **Safe to Operate?:** No — Risk of Damage
- **DIY Difficulty:** Professional Recommended
- **Updated:** 2026-11-22T00:00:00Z

## What This Fault Code Means
A Viessmann boiler relies on continuous pumped water flow to extract burner heat from the stainless/aluminum heat exchanger. Unlike soft electronic NTC faults, the **STB (Safety Temperature Limiter / Sicherheits-Temperaturbegrenzer)** is an independent hardwired high-limit thermal trip (~90–100 °C) that cuts power to the gas valve immediately upon trapped steam or localized boiling—resulting in lockout `F2`.

## Technical Thresholds & Specifications
| Parameter / Condition | Factory Spec / Threshold | Note |
| --- | --- | --- |
| Safety Temperature Limiter (STB) Trip | ~90–100 °C (model-dependent) | Hardwired high-limit thermal switch cuts gas valve directly |
| Normal Cold Operating Pressure | 1.0–1.5 bar | Top up external loop only if pressure sits below 1.0 bar when cool |
| Service & Casing Restriction | Certified Gas / SHK Engineer Only | Do not repeatedly reset F2 or remove sealed boiler cover yourself |

## Commonly Affected Models & Service Bulletins
- Viessmann Vitodens 100-W & 200-W Gas Condensing Boilers
- Viessmann Vitodens 050-W, 222-F & 300-W Series
- Viessmann Vitopend 100-W Conventional Gas Boilers

## Common Symptoms
- Boiler shuts down with `F2` fault code, no central heating or hot water, often after kettle-like boiling noises
- Radiators remain completely cold while boiler cabinet pipes feel scorching hot right before shutdown
- External pressure drops erratically or pressure relief discharges if hydraulic steam expansion occurred

## Most Likely Root Causes
- Seized, failing, or severely air-locked **circulation pump** trapping heat inside the primary heat exchanger
- Heavy **sludge, rust, or limescale restriction** choking the plate heat exchanger or flow/return loops
- Closed system isolation valves / all radiator TRVs turned off with zero open bypass path
- Frozen external condensate outlet backing up water (winter) or faulty high-limit **STB thermostat / wiring**

## Tools & Parts Reference
- Radiator bleed key & external filling valve (safe homeowner pressure check only)
- Certified engineer: OEM Viessmann STB Limiter, pump test meter & pressure gauge
- Certified engineer: Flue gas analyzer & power-flush / magnetic descaling equipment

## Step-by-Step Troubleshooting & Fix
1. Verify cold system gauge sits at `1.0–1.5 bar`, open at least 2–3 radiator valves fully, and gently bleed trapped radiator air (re-topping pressure back to `1.0–1.5 bar`).
2. Check visible exterior condensate pipework in sub-zero cold and thaw external ice carefully with warm—never boiling—water before pressing **one** single Reset after cool-down.
3. Do NOT keep hitting reset if `F2` returns quickly—turn the boiler off at the fused spur/control and call a Gas Safe / certified heating engineer.
4. The engineer inspects and frees or replaces a jammed **circulation pump**, cleans magnetite/scale from the heat exchanger, verifies the diverter valve and auto air vent, or replaces a drifted high-limit **STB sensor**.

## Estimated Repair Cost Benchmark
| Currency | DIY Parts Only | Professional Repair (Parts + Labor) |
| --- | --- | --- |
| USD | $0–$0 | $140–$540 |
| GBP | £0–£0 | £100–£390 |
| CAD | CA$0–CA$0 | CA$180–CA$650 |
| EUR | €0–€0 | €120–€460 |
| CHF | CHF 0–CHF 0 | CHF 195–CHF 690 |

## Frequently Asked Questions
### Is Viessmann fault F2 dangerous if I keep pressing reset?
Yes—repeatedly forcing an STB overheat lockout resets the burner while water isn't circulating, risking steam flashes, pressure relief valve blowouts, or severe heat-exchanger damage. Only perform one reset after verifying cold pressure and cooling down.

### What temperature triggers the Viessmann F2 STB safety cutoff?
Depending on the exact Vitodens/Vitopend platform and firmware safety margin, the hardwired STB trips once primary flow reaches roughly `90 °C to 100 °C`.


## Verified Official & Engineering References
- [Viessmann UK: Official Boiler Fault Codes Guide (F2 Overheat)](https://www.viessmann.co.uk/en/heating-advice/boilers/viessmann-boiler-fault-codes.html) (Official Support)
- [Viessmann Deutschland: Fehlermeldungen & Störungen (F2)](https://www.viessmann.de/de/wissen/fehlermeldungen.html) (Official Support)
- [Viessmann International Official Support](https://www.viessmann.com) (Official Support)