# Baxi E133: Baxi Boiler Error E133: Gas Supply / Ignition Failure Lockout

> **Quick Answer:** Baxi error **`E133`** (*Interruption of gas supply / Flame failure*) is a critical combustion lockout set when the boiler fails to ignite or sustain an ionization flame signal after five startup attempts. In freezing weather, first inspect the **external white/grey condensate drain pipe** for ice blockage (thaw safely with warm—not boiling—water), confirm your **gas emergency control valve is open** and other gas appliances work, and perform **one reset** (`turn selector to R / hold Reset 3–5s`). **COMBUSTION SAFETY WARNING:** Never remove the outer combustion case or tamper with gas valves, spark/sensing electrodes, or flues—only a **Gas Safe registered engineer (UK) or DVGW-certified heating technician (DE/EU)** is legally permitted to work inside the gas/combustion chamber ($0 if thawed condensate/gas meter credit; $145–$580 professional electrode, gas valve, or PCB repair).

- **URL:** https://faultcodes.org/hvac/baxi-e133
- **Category:** HVAC, Boilers & Heating
- **Brand / Standard:** Baxi
- **System Area:** Gas Ignition & Flame Sensing
- **Severity:** Critical — Stop Immediately
- **Safe to Operate?:** No — Risk of Damage
- **DIY Difficulty:** Professional Recommended
- **Updated:** 2026-11-23T00:00:00Z

## What This Fault Code Means
On Baxi Duo-tec, Platinum, EcoBlue, and Main boilers, the PCB checks fan proof, opens the gas valve, fires the spark generator, and verifies flame rectification via the sensing electrode. Whether gas is absent (`closed cock / meter governor fault`), condensate backs up and drowns the burner sump, or the ionization probe fails to read `≥ 1 µA`, `E133` locks the boiler out safely.

## Technical Thresholds & Specifications
| Parameter / Condition | Factory Spec / Threshold | Note |
| --- | --- | --- |
| Ignition Lockout Sequence | 5 failed ignition / flame-sensing retries | Requires manual user Reset (R) once external cause is cleared |
| Condensate Pipe Freeze Prevention | ≥ 32 mm external diameter + waterproof UV lagging | 19/21.5 mm unlagged external pipes freeze rapidly below 0°C |
| Gas & Combustion Compliance | 20 mbar G20 inlet / Gas Safe or DVGW engineer required | Combustion CO2 % calibration required after gas valve replacement |

## Commonly Affected Models & Service Bulletins
- Baxi Duo-tec Combi / GA / HE Series
- Baxi Platinum Combi & Baxi 600 / 800 Series
- Baxi EcoBlue Advance / Main Eco Compact Boilers

## Common Symptoms
- Display flashes `E133` with zero heating or hot water
- During winter cold snaps, gurgling noises occur from the boiler before locking out on `E133` due to frozen condensate
- Fan runs and ignition clicks rapidly, sometimes lighting briefly for 2 seconds before cutting off

## Most Likely Root Causes
- Frozen external **condensate pipe** during sub-zero weather backing water into the combustion chamber
- Gas supply interruption (shut meter valve, depleted prepayment smart meter credit, empty LPG bulk tank, or frozen gas meter regulator)
- Soiled, cracked, or misaligned **flame sensing / ignition electrode** or broken HT ignition lead
- Sticking **gas valve** (`20 mbar` inlet / incorrect burner CO2 calibration), blocked flue/air intake, or failed PCB ignition relay

## Tools & Parts Reference
- Warm water / hot water bottle & waterproof pipe lagging (condensate thaw only)
- Calibrated gas pressure manometer & flue gas analyzer (Gas Safe / DVGW engineer)
- Microamp meter & electrode gap gauge (certified engineer)

## Step-by-Step Troubleshooting & Fix
1. Do **not** open the boiler front cover or touch internal gas components; if you smell gas, turn off the gas emergency valve, extinguish flames, ventilate, and call the gas emergency line.
2. Thaw any frozen external condensate pipe safely with warm water (never boiling water, which can crack PVC pipework) and arrange lagging / `32 mm` upgrade to prevent recurrence.
3. Have a **Gas Safe / DVGW certified engineer** clean the internal condensate trap, inspect/replace the **ignition and flame-sensing electrodes**, and check flue seals.
4. Have the engineer test gas valve coil resistance and dynamic meter governor pressure (`> 18 mbar` at full fire), replace a faulty gas valve or PCB if proven, and verify safe combustion using a calibrated flue gas analyzer.

## Estimated Repair Cost Benchmark
| Currency | DIY Parts Only | Professional Repair (Parts + Labor) |
| --- | --- | --- |
| USD | $0–$15 | $165–$580 |
| GBP | £0–£12 | £115–£430 |
| CAD | CA$0–CA$20 | CA$220–CA$760 |
| EUR | €0–€15 | €145–€540 |
| CHF | CHF 0–CHF 20 | CHF 205–CHF 700 |

## Frequently Asked Questions
### Why does Baxi E133 happen mostly during freezing winter mornings?
Condensing boilers discharge slightly acidic water through an external plastic pipe. In freezing winds, uninsulated external elbows freeze solid, backing water up into the burner chamber and triggering `E133`.

### How do I reset Baxi Error E133 safely?
Check the gas supply and thaw any frozen condensate pipe first, then turn the mode dial to `R` (or press/hold the `Reset` button per your model) for 3–5 seconds. If `E133` returns after 1–2 tries, stop resetting and call a Gas Safe / DVGW engineer.


## Verified Official & Engineering References
- [Baxi UK Official Error Codes & Frozen Condensate Guide (E133)](https://www.baxi.co.uk/) (Official Support)
- [Gas Safe Register Official UK Boiler & Gas Safety Guidance](https://www.gassaferegister.co.uk/) (Regulation / Standard)